Skip to main content

Table 1 Regression equations, R2, Calibration range, LOD, LOQ and retention time (min.) of the tested cannabinoids

From: Evaluation of dispensaries’ cannabis flowers for accuracy of labeling of cannabinoids content

Compound

Regression equation

R2

Calibration range (% w/w)

LOD (% w/w)

LOQ (% w/w)

Retention time (min.)

THCV

y = 0.4141x–0.0029

0.9992

0.01–0.5

0.005

0.01

7.30

CBD

y = 0.359x–0.0032

0.9997

0.01–70

0.005

0.01

8.23

CBC

y = 0.3064x–0.0027

0.9999

0.01–3

0.005

0.01

8.33

Δ8-THC

y = 0.3174x–0.0021

0.9999

0.01–3

0.005

0.01

8.85

Δ9-THC

y = 0.3669x + 0.0002

0.9998

0.01–70

0.005

0.01

9.03

CBG

y = 0.3461x–0.0113

0.997

0.01–3

0.005

0.01

9.62

CBN

y = 0.3286x + 0.0052

0.9989

0.01–3

0.005

0.01

9.72

I.S

-

-

-

-

-

10.07